Independent Lab Landscape

Peptide Testing Labs Compared: Janoshik vs ILS vs Vanguard vs Freedom Diagnostics

Last reviewed October 15, 2026 · Sources listed below · Corrections welcome at info@ashenresearch.com

Researchers comparing third-party peptide testing labs often start with four names: Janoshik Analytical, ILS Laboratories, Vanguard Laboratory and Freedom Diagnostics Testing. This page sets them against the criteria explained in How to Choose a Peptide Testing Lab, using what each lab publishes about itself, public accreditation records, and independent directories.

It is a record of public information, not a ranking. We did not submit samples to these labs. An empty or “not found” entry means we could not find the detail published; it is not a finding that the lab does not do something.

Disclosure

Ashen Research works with several independent labs, including Freedom Diagnostics Testing, Janoshik Analytical and ILS Laboratories, and may add others such as Vanguard Laboratory. Some lots are tested through the COA Coalition, a shared testing program for independent vendors. Ashen Research pays for its testing, directly or through its share of the Coalition’s costs, and receives no compensation from any lab on this page.

Side-by-side comparison

  • Verified found in an accreditation body’s directory or on the lab’s own certificate
  • Stated the lab’s website or reports say so
  • Reported independent directories or reviews; not confirmed by the lab
  • Not found not located in published materials
Criterion Janoshik AnalyticalILS LaboratoriesVanguard LaboratoryFreedom Diagnostics Testing
Location ReportedPrague, Czech RepublicStatedSan Diego, CaliforniaVerifiedOlympia, WashingtonReportedFranklin, Tennessee
ISO/IEC 17025 accreditation ReportedNot claimed by the lab; independent directories list noneStatedClaims accreditation “within its accredited scope”; its certificates cite a PJLA scope. Certificate number and scope not found on its website, so not verified hereVerifiedA2LA certificate 6377.01, valid through Sept. 30, 2027ReportedNot claimed on the certificates we reviewed; independent directories list none
Are the peptide tests on the accredited scope? Not applicableNot foundScope document not locatedVerifiedNot listed. The Dec. 22, 2025 scope lists food microbiology, gluten, preservatives, trace elements by ICP-MS and residual solvents. It does not list peptide purity, identity, endotoxin or sterility methodsNot applicable
Identity method ReportedHPLC-based identity in the base test; LC-MS offered (sources differ on whether it is standard or on request)StatedHPLC retention-time matching against reference standards; LC-MS identity is a custom add-onStatedIdentity included in every tier; method not named on its peptide pageStatedLC-MS with mass confirmation shown on its certificates
Purity method ReportedHPLC with UV detectionStatedReversed-phase HPLC (cites USP <621>)StatedHPLC; says its methods are validated to USP <1225>StatedHPLC-UV
Net content ReportedAmount per vial reported in the base testStatedQuantitation per vial in the HPLC panelStated“Quantity” included in every tierStatedNet content shown on its certificates
Endotoxin ReportedAvailable as an add-onStatedUSP <85> kinetic chromogenic LAL, reported in EU/mgStatedFollows USP <85> methodologyStatedLAL per USP <85>. On the certificates we reviewed, results are pass/fail with a stated sensitivity (≤0.05 EU/mL), not a numeric value
Sterility ReportedAvailable on request; method not specified in the sources we foundStatedRapid DNA-microarray screen (not the USP <71> culture test)StatedUSP <71>, 14-day testing periodNot foundNot in its published test list
Elemental impurities (heavy metals) ReportedAvailable on requestStatedICP-MS, references ICH Q3DStatedICP-MS for arsenic, cadmium, chromium, mercury, lead. The ICP-MS trace-element method (EPA 200.8, modified) is on its accredited scopeNot foundNot in its published test list
Report verification ReportedUnique key and QR code, checked on its public databaseStatedQR-verified reports and a public verify pageStatedQR code opens the latest version of the reportStatedSearch code on each report for public lookup
Typical turnaround ReportedAbout 4 days to 2 weeksStatedAbout 1 week; rush 3 business daysStated7–10 business days; sterility 14 daysReportedAbout 2–4 days

Details checked October 15, 2026. Labs change methods, prices and scopes; verify with the lab before relying on any entry.

What the public record shows

  • Accreditation. Vanguard is the only one of the four with an accreditation we could verify in a public directory. Its scope, dated December 22, 2025, lists trace-element, residual-solvent, preservative, gluten and food-microbiology methods but not peptide purity, identity, endotoxin or sterility. ILS states it is accredited but publishes no certificate number we could find. Janoshik and Freedom do not claim ISO/IEC 17025 accreditation.
  • Identity. Freedom’s certificates show LC-MS identity with mass confirmation. ILS’s standard identity check is HPLC retention-time matching, with LC-MS as an add-on. Reports on Janoshik differ on whether LC-MS is standard. Vanguard does not name its identity method on its peptide page.
  • Contaminant panels. ILS and Vanguard both publish endotoxin, sterility and ICP-MS heavy-metal options. Freedom’s published list covers purity and identity, net content and endotoxin. Janoshik offers add-ons on request.
  • Sterility methods differ. Vanguard uses the compendial USP <71> culture test over 14 days. ILS uses a rapid DNA-microarray screen. Rapid methods are alternative methods that must be shown to be equivalent to the compendial test.10
  • Endotoxin reporting differs. ILS reports a numeric EU/mg value. Freedom’s certificates we reviewed report pass/fail with a stated sensitivity.

Matching a lab to your need

  • You need accreditation documentation: Vanguard is the only one of the four with a verifiable accreditation. Confirm the specific test you need is on its scope; as of the December 2025 scope, peptide HPLC is not.
  • You want mass-spectrometry identity on the report: Freedom’s certificates show it. Ask the other labs which identity method applies to your order.
  • You need a numeric endotoxin value: ILS states EU/mg reporting. Ask the others for a sample report.
  • You need the compendial 14-day sterility test: Vanguard lists USP <71>. ILS offers a rapid screen instead.
  • You want elemental (ICP-MS) results: ILS and Vanguard publish it; Janoshik offers it on request.

Lab profiles

Janoshik Analytical

A Prague-based independent lab that independent directories describe as the most widely referenced in the research-peptide community. Reports carry a unique key and QR code that can be checked on its public database. It does not report ISO/IEC 17025 accreditation. Most details in this column come from third-party directories because the lab’s own scope of services is not published in one place we could read. 8

ILS Laboratories

A San Diego lab with published panel pricing and QR-verified reports. Its standard identity check is HPLC retention-time matching, with LC-MS as an add-on, and it sells endotoxin (USP <85>), a rapid sterility screen and ICP-MS heavy metals. It states ISO/IEC 17025 accreditation for its scope; ask the lab for its certificate number and scope. 5, 6

Vanguard Laboratory

An Olympia, Washington lab (Olympic Analytical, LLC) that holds an A2LA ISO/IEC 17025 accreditation, with a scope covering food microbiology, trace elements by ICP-MS and residual solvents. Its peptide tiers add endotoxin, USP <71> sterility and ICP-MS heavy metals. It states its peptide HPLC methods are validated to USP <1225>; that is a method-validation statement, separate from accreditation. 1, 2, 3, 4

Freedom Diagnostics Testing

A Franklin, Tennessee lab whose certificates show LC-MS identity, HPLC-UV purity, net content and LAL endotoxin testing per USP <85>, with a search code for public lookup. It does not claim ISO/IEC 17025 accreditation on the certificates we reviewed, and its published test list does not include sterility or heavy metals. 7, 9

Limits of this comparison

  • It uses public information. We did not audit these labs or submit samples, and the Janoshik column relies mostly on third-party reports.
  • Labs update methods, scopes and prices. The review date at the top shows when entries were last checked.
  • Verify any accreditation claim yourself in the accreditation body’s directory. Certificate numbers are sometimes quoted for the wrong lab.
  • If a detail here is out of date or wrong, email info@ashenresearch.com and we will review and update it.

Frequently asked questions

Is Freedom Diagnostics ISO 17025 accredited?

Freedom Diagnostics Testing does not claim ISO/IEC 17025 accreditation on the certificates we reviewed, and the independent directories we checked list none, as of October 15, 2026. Its certificates report LC-MS identity, HPLC-UV purity, net content and LAL endotoxin testing per USP <85>. Check the accreditation body’s directory before relying on any lab’s accreditation claim.7, 9

Is Janoshik ISO 17025 accredited?

Janoshik Analytical does not report ISO/IEC 17025 accreditation, and independent directories list none. Researchers commonly cite its public report verification and its wide use among suppliers.8

Is ILS Labs ISO 17025 accredited?

ILS Laboratories states that it is accredited for activities within its accredited scope, and its certificates refer to a published PJLA scope. We could not find a certificate number or scope document on its website, so we list the claim as stated, not verified. You can ask the lab for its certificate and scope.5, 6

Is Vanguard Laboratory accredited for peptide testing?

Vanguard holds ISO/IEC 17025:2017 accreditation from A2LA (certificate 6377.01, valid through September 30, 2027). The scope document dated December 22, 2025 lists food-microbiology, gluten, preservative, trace-element (ICP-MS) and residual-solvent methods. It does not list peptide purity, identity, endotoxin or sterility methods. Vanguard’s website says its peptide HPLC methods are validated to USP <1225>.1, 3, 4

Which of these labs offers sterility testing?

Vanguard lists USP <71> sterility (14-day). ILS lists a rapid DNA-microarray sterility screen. Janoshik is reported to offer sterility on request. Sterility was not in Freedom’s published test list.1, 5

Which peptide testing labs does Ashen Research use?

Ashen Research works with several independent labs, including Freedom Diagnostics Testing, Janoshik Analytical and ILS Laboratories, and may add others such as Vanguard Laboratory. The lab that tested a lot, and who the report is issued to, are shown next to that lot’s results on its product page. Some lots are tested through the COA Coalition, a shared testing program for independent vendors.

Which peptide testing lab is best?

It depends on what you need the report to show; no lab in this comparison leads on every criterion. See How to Choose a Peptide Testing Lab for the criteria, and use the table above to match a lab to your need.

Sources

For in vitro laboratory research only. Not for human or veterinary use. This page summarizes public information about third-party laboratories for educational purposes. Ashen Research is not affiliated with these laboratories beyond being a customer of the labs it uses.

Cart

Your cart is currently empty.

Subtotal$0.00
Proceed to Checkout